API java : GaugeMonitorMBean


javax.management.monitor
Interface GaugeMonitorMBean

All Superinterfaces:
MonitorMBean
All Known Implementing Classes:
GaugeMonitor

public interface GaugeMonitorMBean
extends MonitorMBean

Exposes the remote management interface of the gauge monitor MBean.

Since:
1.5

Method Summary
 Number getDerivedGauge()
          Deprecated. As of JMX 1.2, replaced by getDerivedGauge(ObjectName)
 Number getDerivedGauge(ObjectName object)
          Gets the derived gauge for the specified MBean.
 long getDerivedGaugeTimeStamp()
          Deprecated. As of JMX 1.2, replaced by getDerivedGaugeTimeStamp(ObjectName)
 long getDerivedGaugeTimeStamp(ObjectName object)
          Gets the derived gauge timestamp for the specified MBean.
 boolean getDifferenceMode()
          Gets the difference mode flag value.
 Number getHighThreshold()
          Gets the high threshold value.
 Number getLowThreshold()
          Gets the low threshold value.
 boolean getNotifyHigh()
          Gets the high notification's on/off switch value.
 boolean getNotifyLow()
          Gets the low notification's on/off switch value.
 void setDifferenceMode(boolean value)
          Sets the difference mode flag value.
 void setNotifyHigh(boolean value)
          Sets the high notification's on/off switch value.
 void setNotifyLow(boolean value)
          Sets the low notification's on/off switch value.
 void setThresholds(Number highValue, Number lowValue)
          Sets the high and the low threshold values.
 
Methods inherited from interface javax.management.monitor.MonitorMBean
addObservedObject, containsObservedObject, getGranularityPeriod, getObservedAttribute, getObservedObject, getObservedObjects, isActive, removeObservedObject, setGranularityPeriod, setObservedAttribute, setObservedObject, start, stop
 

Method Detail

getDerivedGauge

@Deprecated
Number getDerivedGauge()
Deprecated. As of JMX 1.2, replaced by getDerivedGauge(ObjectName)

Gets the derived gauge.

Returns:
The derived gauge.

getDerivedGaugeTimeStamp

@Deprecated
long getDerivedGaugeTimeStamp()
Deprecated. As of JMX 1.2, replaced by getDerivedGaugeTimeStamp(ObjectName)

Gets the derived gauge timestamp.

Returns:
The derived gauge timestamp.

getDerivedGauge

Number getDerivedGauge(ObjectName object)
Gets the derived gauge for the specified MBean.

Parameters:
object - the MBean for which the derived gauge is to be returned
Returns:
The derived gauge for the specified MBean if this MBean is in the set of observed MBeans, or null otherwise.

getDerivedGaugeTimeStamp

long getDerivedGaugeTimeStamp(ObjectName object)
Gets the derived gauge timestamp for the specified MBean.

Parameters:
object - the MBean for which the derived gauge timestamp is to be returned
Returns:
The derived gauge timestamp for the specified MBean if this MBean is in the set of observed MBeans, or null otherwise.

getHighThreshold

Number getHighThreshold()
Gets the high threshold value.

Returns:
The high threshold value.

getLowThreshold

Number getLowThreshold()
Gets the low threshold value.

Returns:
The low threshold value.

setThresholds

void setThresholds(Number highValue,
                   Number lowValue)
                   throws IllegalArgumentException
Sets the high and the low threshold values.

Parameters:
highValue - The high threshold value.
lowValue - The low threshold value.
Throws:
IllegalArgumentException - The specified high/low threshold is null or the low threshold is greater than the high threshold or the high threshold and the low threshold are not of the same type.

getNotifyHigh

boolean getNotifyHigh()
Gets the high notification's on/off switch value.

Returns:
true if the gauge monitor notifies when exceeding the high threshold, false otherwise.
See Also:
setNotifyHigh(boolean)

setNotifyHigh

void setNotifyHigh(boolean value)
Sets the high notification's on/off switch value.

Parameters:
value - The high notification's on/off switch value.
See Also:
getNotifyHigh()

getNotifyLow

boolean getNotifyLow()
Gets the low notification's on/off switch value.

Returns:
true if the gauge monitor notifies when exceeding the low threshold, false otherwise.
See Also:
setNotifyLow(boolean)

setNotifyLow

void setNotifyLow(boolean value)
Sets the low notification's on/off switch value.

Parameters:
value - The low notification's on/off switch value.
See Also:
getNotifyLow()

getDifferenceMode

boolean getDifferenceMode()
Gets the difference mode flag value.

Returns:
true if the difference mode is used, false otherwise.
See Also:
setDifferenceMode(boolean)

setDifferenceMode

void setDifferenceMode(boolean value)
Sets the difference mode flag value.

Parameters:
value - The difference mode flag value.
See Also:
getDifferenceMode()

Ces informations proviennent du site de http://java.sun.com

Remarques

Contenu

Le contenu de cette page provient du site de Sun, et est généré depuis un cache sur l'infobrol après certains traitements automatisés. La présentation peut donc différer du document original, mais le contenu aussi. Vous pouvez utiliser ce bouton pour afficher la page originale du site de Sun :

Quels sont les motivations de cette démarche?

Maintenir les pages en cache sur différents sites peut offrir plus de disponibilité.

Chaque page est indexée dans la base de donnée, ce qui permet de retrouver facilement les informations, au moyen des sommaires, du moteur de recherche interne, etc.

Des facilités sont mises en place pour que les membres de l'infobrol puissent effectuer des traductions en français des différents documents. Ceci devrait permettre aux débutants en programmation Java de consulter les API en français s'ils maîtrisent moins bien la langue de Shakespeare. Dans le cas où une traduction a été soumise, elle est disponible au moyen d'un lien en bas de page. Si la traduction a été validée, la page s'affiche par défaut en français, et un lien en bas de page permet d'atteindre la version en anglais.

Le code sur l'infobrol est automatiquement coloré selon la syntaxe, et les différents mots clés sont transformés en liens pour accéder rapidement aux informations.

Vous avez la possibilité de partager vos expériences en proposant vos propres extraits de code en utilisant le bouton "ajouter un commentaire" en bas de page. Si vous visitez simplement l'infobrol, vous avez déjà accès à cette fonction, mais si vous étes membre du brol, vous pouvez en plus utiliser des boutons supplémentaires de mise en forme, dont la coloration automatique de vos extraits de codes.

Réseaux sociaux

Vous pouvez modifier vos préférences dans votre profil pour ne plus afficher les interactions avec les réseaux sociaux sur ces pages.

 

Nuage de mots clés

7 mots clés dont 0 définis manuellement (plus d'information...).

Avertissement

Cette page ne possède pas encore de mots clés manuels, ceci est donc un exemple automatique (les niveaux de pertinence sont fictifs, mais les liens sont valables). Pour tester le nuage avec une page qui contient des mots définis manuellement, vous pouvez cliquer ici.

Vous pouvez modifier vos préférences dans votre profil pour ne plus afficher le nuage de mots clés.

 

Astuce pour imprimer les couleurs des cellules de tableaux : http://www.gaudry.be/ast-rf-450.html
Aucun commentaire pour cette page

© Ce document issu de l′infobrol est enregistré sous le certificat Cyber PrInterDeposit Digital Numbertection. Enregistrement IDDN n° 5329-3030
Document créé le 01/09/06 00:44, dernière modification le Vendredi 17 Juin 2011, 12:12
Source du document imprimé : http://www.gaudry.be/java-api-rf-javax/management/monitor/GaugeMonitorMBean.html Document affiché 1 fois ce mois de Juin.
St.Gaudry©07.01.02
 
l'infobrol
Nous sommes le Samedi 02 Juin 2012, 00:28, toutes les heures sont au format GMT+1.00 Heure, heure d'été (+1)